Fault Injection & Debugging

# GNSS UBX and NMEA fix-loss and checksum fault testing

Drop GNSS fix validity or corrupt UBX checksums mid-mission and verify clean failsafe transition in headless CI.

Navigation parsers frequently crash or feed zeroed latitude/longitude into controllers when a tunnel drops fixType from 3D (3) to No Fix (0) or truncates a UBX-NAV-PVT packet.

CircuitTwin includes u-blox UBX frame modeling (kinds\_ubx.rs) so CI can drive trajectories, drop satellite count, and inject UART dropouts deterministically.

## GNSS parser fault scenarios

| Fault              | UBX / NMEA field                | Expected firmware check                                  |
| ------------------ | ------------------------------- | -------------------------------------------------------- |
| Fix loss (tunnel)  | UBX-NAV-PVT fixType=0, numSV=2  | Controller rejects stale coordinates and enters failsafe |
| Bad Fletcher-8 CRC | Flip CK\_A / CK\_B on UBX frame | Parser discards packet and re-syncs on 0xB5 0x62         |
| UART RX dropout    | uart\_drop\_rx for 2000 ms      | GNSS health watchdog flags timeout cleanly               |

## Local CLI workflow

Shell - run GNSS fix-loss test suite

```
ct test run --json --junit results/gnss.xml tests/gnss-fixloss.suite.yaml
```

## Suite & fault configuration

tests/gnss-fixloss.suite.yaml

```
version: 1
board: nucleo-h743zi2
firmware: build/nav_ctrl.elf
tests:
  - name: ubx-uart-dropout-failsafe
    timeout_ms: 4000
    faults:
      - at_ms: 800
        part: neo-m9n
        kind: uart_drop_rx
        duration_ms: 1500
    expect:
      console_contains: "GNSS_TIMEOUT_FAILSAFE"
      exit_code: 0
```

## CI pipeline integration

.github/workflows/gnss-ci.yml

```
name: GNSS Parser Fault CI
on: [push, pull_request]
jobs:
  gnss:
    runs-on: ubuntu-latest
    steps:
      - uses: actions/checkout@v4
      - uses: circuittwin/action@v1
        with:
          suite: tests/gnss-fixloss.suite.yaml
```

## Troubleshooting checklist

| Symptom                                              | Fix                                                                                                   |
| ---------------------------------------------------- | ----------------------------------------------------------------------------------------------------- |
| Parser stops receiving after one truncated UBX frame | Reset state machine to sync byte 0xB5 whenever payload length exceeds buffer limit or checksum fails. |

## Frequently asked questions

| Question                                                                     | Answer                                                                                                                    |
| ---------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------- |
| Does CircuitTwin support binary u-blox UBX frames as well as NMEA sentences? | Yes. The u-blox GNSS model supports UBX binary framing (0xB5 0x62 sync + Fletcher checksum) and NMEA sentences over UART. |

## Related boards & component twins

[Board: nucleo-h743zi2](https://circuittwin.ai/boards/nucleo-h743zi2) [Board: nucleo-f767zi](https://circuittwin.ai/boards/nucleo-f767zi) [Board: teensy-4-1](https://circuittwin.ai/boards/teensy-4-1) [Twin: NEO-M9N](https://circuittwin.ai/twins/neo-m9n) [Twin: ICM-42688-P](https://circuittwin.ai/twins/icm-42688-p) [Twin: MS5611](https://circuittwin.ai/twins/ms5611) [NEO-M9N GNSS twin](https://circuittwin.ai/twins/neo-m9n)

## More in Fault Injection & Debugging

[I2C NACK and stuck-bus fault injection in CI](https://circuittwin.ai/guides/i2c-nack-fault-injection) [SPI bus fault testing and chip-select verification](https://circuittwin.ai/guides/spi-bus-fault-testing) [Debugging UART baud mismatches and framing errors](https://circuittwin.ai/guides/uart-baud-mismatch-debugging) [Cortex-M HardFault triage in CI and reverse GDB](https://circuittwin.ai/guides/cortex-m-hardfault-ci-triage)

> ## Run this workflow on your own ELF
>
> Start free on CircuitTwin to run local board twins, fault matrices and CI checks with zero per-run credits.
>
> [Start now](https://app.circuittwin.ai/try) [Read the quickstart](https://circuittwin.ai/docs/quickstart) [Connect a coding agent](https://circuittwin.ai/docs/agents)