Compliance & Verification

# IEC 62304 Class C medical firmware anomaly testing

Exercise every alarm state and sensor-fault mitigation on your real compiled MCU binary on every pull request.

IEC 62304 Class C software demands thorough anomaly and boundary verification of segregated safety items. Manual bench tests cannot cover every combination of stuck sensors, NACK bursts and watchdog trips after every hotfix.

CircuitTwin turns medical firmware anomaly tests into version-controlled YAML suites that execute identically on developer laptops and locked CI runners.

## Class C anomaly checks

| Hazard control              | Fault injected                         | Verification assertion                         |
| --------------------------- | -------------------------------------- | ---------------------------------------------- |
| Stuck pressure/flow reading | frozen\_reading on I2C pressure sensor | Firmware detects stale sample and raises alarm |
| Bus lockup                  | Sustained I2C NACK burst               | 9-clock bus recovery executes within deadline  |
| Memory corruption           | MPU stack guard / MemManage test       | Safe-state actuator cutoff engages immediately |

## Local CLI workflow

Shell - run IEC 62304 anomaly suite

```
ct test run --json --recheck --junit results/iec62304.xml tests/class-c-anomalies.suite.yaml
```

## Suite & fault configuration

tests/class-c-anomalies.suite.yaml

```
version: 1
board: nucleo-l476rg
firmware: build/infusion_ctrl.elf
tests:
  - name: pressure-sensor-frozen-alarm
    timeout_ms: 3000
    faults:
      - at_ms: 400
        part: bmp390
        kind: frozen_reading
    expect:
      console_contains: "ALARM_STALE_PRESSURE"
      exit_code: 0
```

## CI pipeline integration

.github/workflows/iec62304-ci.yml

```
name: IEC 62304 Verification CI
on: [push, pull_request]
jobs:
  class-c:
    runs-on: ubuntu-latest
    steps:
      - uses: actions/checkout@v4
      - uses: circuittwin/action@v1
        with:
          suite: tests/class-c-anomalies.suite.yaml
          junit-out: results/iec62304.xml
```

## Troubleshooting checklist

| Symptom                              | Fix                                                                                               |
| ------------------------------------ | ------------------------------------------------------------------------------------------------- |
| Stale sensor reading goes undetected | Compare consecutive raw ADC samples or check sensor status/counter bits before trusting readings. |
| Alarm latency exceeds spec           | Inspect exact virtual-time delta between fault timestamp and console alarm in the JSON output.    |

## Frequently asked questions

| Question                                                    | Answer                                                                                                          |
| ----------------------------------------------------------- | --------------------------------------------------------------------------------------------------------------- |
| Can virtual-time timestamps measure alarm response latency? | Yes. Every fault injection and console line carries a deterministic virtual-time timestamp in the JSON run log. |

## Related boards & component twins

[Board: nucleo-l476rg](https://circuittwin.ai/boards/nucleo-l476rg) [Board: nucleo-l552ze](https://circuittwin.ai/boards/nucleo-l552ze) [Board: nrf52840-dk](https://circuittwin.ai/boards/nrf52840-dk) [Twin: BMP390](https://circuittwin.ai/twins/bmp390) [Twin: MAX30102](https://circuittwin.ai/twins/max30102) [Twin: TMP117](https://circuittwin.ai/twins/tmp117) [Compliance & audit docs](https://circuittwin.ai/docs/compliance)

## More in Compliance & Verification

[EU Cyber Resilience Act (CRA) firmware testing evidence](https://circuittwin.ai/guides/eu-cra-firmware-testing-evidence) [ISO 26262 firmware fault-injection & traceability support](https://circuittwin.ai/guides/iso-26262-firmware-verification) [DO-178C firmware testing and traceability workflows](https://circuittwin.ai/guides/do-178c-firmware-traceability) [FDA Section 524B medical device firmware testing support](https://circuittwin.ai/guides/fda-524b-medical-device-cybersecurity-testing)

> ## Run this workflow on your own ELF
>
> Start free on CircuitTwin to run local board twins, fault matrices and CI checks with zero per-run credits.
>
> [Start now](https://app.circuittwin.ai/try) [Read the quickstart](https://circuittwin.ai/docs/quickstart) [Connect a coding agent](https://circuittwin.ai/docs/agents)