Compliance & Verification

# IEC 62443-4-2 industrial security robustness testing

Verify industrial gateway firmware rejects malformed Ethernet, Modbus RTU and CAN frames without HardFaults or watchdog locks.

Industrial automation controllers face strict IEC 62443-4-2 component security requirements covering input validation, resource exhaustion and deterministic recovery from communication loss.

Running compiled PLC or gateway ELFs on CircuitTwin lets security teams replay malformed frame corpora deterministically in CI on every commit.

## IEC 62443-4-2 robustness tests

| Requirement area         | Twin fault / stimulus                             | Pass criterion                                  |
| ------------------------ | ------------------------------------------------- | ----------------------------------------------- |
| Input validation         | Oversized Modbus RTU / UART payloads with bad CRC | Zero HardFaults; parser resets cleanly          |
| DoS / flood resilience   | Burst CAN frames and Ethernet packet drops        | Control loop watchdog remains fed               |
| Secure storage integrity | External flash bit-flip on config sector          | CRC check fails closed to factory safe defaults |

## Local CLI workflow

Shell - run IEC 62443 robustness suite

```
ct test run --json --junit results/iec62443.xml tests/iec62443-security.suite.yaml
```

## Suite & fault configuration

tests/iec62443-security.suite.yaml

```
version: 1
board: nucleo-f767zi
firmware: build/plc_gateway.elf
tests:
  - name: eth-link-flap-and-watchdog-health
    timeout_ms: 4000
    faults:
      - at_ms: 300
        part: lan8720a
        kind: link_down
        duration_ms: 600
    expect:
      console_contains: "GATEWAY_RECOVERED"
      exit_code: 0
```

## CI pipeline integration

.github/workflows/iec62443-ci.yml

```
name: IEC 62443 Robustness CI
on: [push, pull_request]
jobs:
  sec:
    runs-on: ubuntu-latest
    steps:
      - uses: actions/checkout@v4
      - uses: circuittwin/action@v1
        with:
          suite: tests/iec62443-security.suite.yaml
```

## Troubleshooting checklist

| Symptom                                          | Fix                                                                                          |
| ------------------------------------------------ | -------------------------------------------------------------------------------------------- |
| Malformed frame causes unaligned read UsageFault | Decode CFSR.UNALIGNED in the HardFault Decoder and replace packed pointer casts with memcpy. |
| Gateway hangs after Ethernet link drops          | Verify PHY BSR link polling clears stalled DMA RX descriptors.                               |

## Frequently asked questions

| Question                                                                   | Answer                                                                                                                     |
| -------------------------------------------------------------------------- | -------------------------------------------------------------------------------------------------------------------------- |
| Can CircuitTwin test Ethernet link-down recovery without a managed switch? | Yes. Inject link\_down faults on LAN8720A or W5500 twins at exact virtual timestamps and assert clean TCP/socket recovery. |

## Related boards & component twins

[Board: nucleo-f767zi](https://circuittwin.ai/boards/nucleo-f767zi) [Board: nucleo-h743zi2](https://circuittwin.ai/boards/nucleo-h743zi2) [Board: xmc4700-relax](https://circuittwin.ai/boards/xmc4700-relax) [Twin: LAN8720A](https://circuittwin.ai/twins/lan8720a) [Twin: W5500](https://circuittwin.ai/twins/w5500) [Twin: MAX3485](https://circuittwin.ai/twins/max3485) [Twin: ATECC608A](https://circuittwin.ai/twins/atecc608a) [Compliance documentation](https://circuittwin.ai/docs/compliance)

## More in Compliance & Verification

[EU Cyber Resilience Act (CRA) firmware testing evidence](https://circuittwin.ai/guides/eu-cra-firmware-testing-evidence) [ISO 26262 firmware fault-injection & traceability support](https://circuittwin.ai/guides/iso-26262-firmware-verification) [DO-178C firmware testing and traceability workflows](https://circuittwin.ai/guides/do-178c-firmware-traceability) [FDA Section 524B medical device firmware testing support](https://circuittwin.ai/guides/fda-524b-medical-device-cybersecurity-testing)

> ## Run this workflow on your own ELF
>
> Start free on CircuitTwin to run local board twins, fault matrices and CI checks with zero per-run credits.
>
> [Start now](https://app.circuittwin.ai/try) [Read the quickstart](https://circuittwin.ai/docs/quickstart) [Connect a coding agent](https://circuittwin.ai/docs/agents)