Current, Power & ADC

# Texas Instruments INA226 digital twin

36 V, 16-bit high/low-side I2C current, voltage and power monitor.

standing: provisional I2C 0x40–0x4F (default 0x40)

Vendor Texas Instruments Current, Power & ADC

Interface I2C 0x40–0x4F (default 0x40)

Record Status 2026-11-19 rev c3f5f9950 (clean tree)

## Driver oracle & capability record

Part of the 27-part, 44-case twin-factory oracle suite (44/44 passed, generator 0.1.0+policy.12).

| Driver reference  | Twin-factory vendor-driver oracle (0.1.0+policy.12)                                                                                                     |
| ----------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Evidence standing | provisional (register and bus behavior derived from vendor datasheet or driver oracle; not yet hardware-unit verified on two physical samples).         |
| Published record  | [accuracy/twin-factory-oracles-2026-11-19b.json](https://circuittwin.ai/evidence/accuracy/twin-factory-oracles-2026-11-19b.json) (SHA-256 caa6e32e53c5) |

## Key registers & reset values

| Address / Field | Register          | Reset / Expected | Purpose                                     |
| --------------- | ----------------- | ---------------- | ------------------------------------------- |
| 0xFE / 0xFF     | MANUF / DIE\_ID   | 0x5449 / 0x2260  | TI manufacturer and INA226 die ID           |
| 0x01 / 0x02     | SHUNT\_V / BUS\_V | 2.5 uV / 1.25 mV | Shunt and bus voltage measurement registers |
| 0x04 / 0x05     | CURRENT / CALIB   | 0x0000           | Calibrated current and calibration register |

## Attach with ct CLI

Shell - run firmware with INA226

```
# Run compiled firmware with INA226 attached on nucleo-g071rb
ct run --json --board nucleo-g071rb --device ina226 build/app.elf

# Run fault-injection suite and emit JUnit XML
ct test run --json --junit results/ina226.xml tests/ina226-fault.suite.yaml
```

## Fault-injection test snippet (suite.yaml)

tests/ina226-fault.suite.yaml

```
version: 1
board: nucleo-g071rb
firmware: build/app.elf
tests:
  - name: ina226-i2c-nack-and-bad-id
    faults:
      - at_ms: 30
        bus: I2C1
        kind: nack
        address: 0x40
        count: 2
      - at_ms: 150
        part: ina226
        kind: register_override
        register: 0xFF
        value: 0xFF
    expect:
      console_contains: "DRIVER_FAULT_DETECTED"
      exit_code: 0
```

## Compatible board twins

[Board: nucleo-g071rb](https://circuittwin.ai/boards/nucleo-g071rb) [Board: arduino-portenta-h7](https://circuittwin.ai/boards/arduino-portenta-h7) [Board: frdm-k64f](https://circuittwin.ai/boards/frdm-k64f) [Accuracy report](https://circuittwin.ai/docs/accuracy)

## More in Current, Power & ADC

[ADS1015 (Texas)](https://circuittwin.ai/twins/ads1015) [ADS1115 (Texas)](https://circuittwin.ai/twins/ads1115) [ADS1220 (Texas)](https://circuittwin.ai/twins/ads1220) [ADS1256 (Texas)](https://circuittwin.ai/twins/ads1256) [BQ27441-G1 (Texas)](https://circuittwin.ai/twins/bq27441-g1) [HX711 (Avia)](https://circuittwin.ai/twins/hx711)

> ## Inject INA226 bus faults in CI
>
> Wire INA226 onto your MCU board twin, drive physical stimuli and fail builds when your driver hangs on NACKs or frozen registers.
>
> [Start now](https://app.circuittwin.ai/try) [Inputs & fault injection docs](https://circuittwin.ai/docs/inputs) [Connect a coding agent](https://circuittwin.ai/docs/agents)
