Current, Power & ADC

# Texas Instruments INA260 digital twin

36 V, 15 A integrated-shunt I2C current and power monitor.

standing: provisional I2C 0x40–0x4F (default 0x40)

Vendor Texas Instruments Current, Power & ADC

Interface I2C 0x40–0x4F (default 0x40)

Record Status 2026-11-19 rev c3f5f9950 (clean tree)

## Driver oracle & capability record

Part of the 27-part, 44-case twin-factory oracle suite (44/44 passed, generator 0.1.0+policy.12).

| Driver reference  | Twin-factory vendor-driver oracle (0.1.0+policy.12)                                                                                                     |
| ----------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Evidence standing | provisional (register and bus behavior derived from vendor datasheet or driver oracle; not yet hardware-unit verified on two physical samples).         |
| Published record  | [accuracy/twin-factory-oracles-2026-11-19b.json](https://circuittwin.ai/evidence/accuracy/twin-factory-oracles-2026-11-19b.json) (SHA-256 caa6e32e53c5) |

## Key registers & reset values

| Address / Field | Register         | Reset / Expected  | Purpose                                         |
| --------------- | ---------------- | ----------------- | ----------------------------------------------- |
| 0xFE / 0xFF     | MANUF / DIE\_ID  | 0x5449 / 0x2270   | TI manufacturer and INA260 die ID               |
| 0x01 / 0x02     | CURRENT / BUS\_V | 1.25 mA / 1.25 mV | Factory-calibrated current and bus voltage      |
| 0x03            | POWER            | 10 mW/LSB         | Direct power readout with internal 2 mOhm shunt |

## Attach with ct CLI

Shell - run firmware with INA260

```
# Run compiled firmware with INA260 attached on nucleo-l552ze
ct run --json --board nucleo-l552ze --device ina260 build/app.elf

# Run fault-injection suite and emit JUnit XML
ct test run --json --junit results/ina260.xml tests/ina260-fault.suite.yaml
```

## Fault-injection test snippet (suite.yaml)

tests/ina260-fault.suite.yaml

```
version: 1
board: nucleo-l552ze
firmware: build/app.elf
tests:
  - name: ina260-i2c-nack-and-bad-id
    faults:
      - at_ms: 30
        bus: I2C1
        kind: nack
        address: 0x40
        count: 2
      - at_ms: 150
        part: ina260
        kind: register_override
        register: 0xFF
        value: 0xFF
    expect:
      console_contains: "DRIVER_FAULT_DETECTED"
      exit_code: 0
```

## Compatible board twins

[Board: nucleo-l552ze](https://circuittwin.ai/boards/nucleo-l552ze) [Board: nucleo-f767zi](https://circuittwin.ai/boards/nucleo-f767zi) [Board: teensy-4-1](https://circuittwin.ai/boards/teensy-4-1) [Accuracy report](https://circuittwin.ai/docs/accuracy)

## More in Current, Power & ADC

[ADS1015 (Texas)](https://circuittwin.ai/twins/ads1015) [ADS1115 (Texas)](https://circuittwin.ai/twins/ads1115) [ADS1220 (Texas)](https://circuittwin.ai/twins/ads1220) [ADS1256 (Texas)](https://circuittwin.ai/twins/ads1256) [BQ27441-G1 (Texas)](https://circuittwin.ai/twins/bq27441-g1) [HX711 (Avia)](https://circuittwin.ai/twins/hx711)

> ## Inject INA260 bus faults in CI
>
> Wire INA260 onto your MCU board twin, drive physical stimuli and fail builds when your driver hangs on NACKs or frozen registers.
>
> [Start now](https://app.circuittwin.ai/try) [Inputs & fault injection docs](https://circuittwin.ai/docs/inputs) [Connect a coding agent](https://circuittwin.ai/docs/agents)