Display, PWM & Haptics

Texas Instruments DRV2605 digital twin

I2C ERM/LRA haptic motor driver with waveform library sequencer.

standing: provisionalI2C0x5A (fixed)
VendorTexas InstrumentsDisplay, PWM & Haptics
InterfaceI2C0x5A (fixed)
Record Status2026-11-19rev c3f5f9950 (clean tree)

Driver oracle & capability record

Part of the 27-part, 44-case twin-factory oracle suite (44/44 passed, generator 0.1.0+policy.12).

Driver referenceTwin-factory vendor-driver oracle (0.1.0+policy.12)
Evidence standingprovisional (register and bus behavior derived from vendor datasheet or driver oracle; not yet hardware-unit verified on two physical samples).
Published recordaccuracy/twin-factory-oracles-2026-11-19b.json (SHA-256 caa6e32e53c5)

Key registers & reset values

Address / FieldRegisterReset / ExpectedPurpose
0x00STATUSBits [7:5] DEV_IDDevice ID, diagnostic and over-temp/current flags
0x01MODE0x40 (STANDBY)Standby exit, internal/external trigger or RTP mode
0x0CGO0x00Write 1 to launch waveform playback sequence

Attach with ct CLI

Shell - run firmware with DRV2605
# Run compiled firmware with DRV2605 attached on arduino-nano
ct run --json --board arduino-nano --device drv2605 build/app.elf

# Run fault-injection suite and emit JUnit XML
ct test run --json --junit results/drv2605.xml tests/drv2605-fault.suite.yaml

Fault-injection test snippet (suite.yaml)

tests/drv2605-fault.suite.yaml
version: 1
board: arduino-nano
firmware: build/app.elf
tests:
  - name: drv2605-i2c-nack-and-bad-id
    faults:
      - at_ms: 30
        bus: I2C1
        kind: nack
        address: 0x5A
        count: 2
      - at_ms: 150
        part: drv2605
        kind: register_override
        register: 0x00
        value: 0xFF
    expect:
      console_contains: "DRIVER_FAULT_DETECTED"
      exit_code: 0

Compatible board twins

More in Display, PWM & Haptics