Current, Power & ADC
Texas Instruments INA260 digital twin
36 V, 15 A integrated-shunt I2C current and power monitor.
VendorTexas InstrumentsCurrent, Power & ADC
InterfaceI2C0x40–0x4F (default 0x40)
Record Status2026-11-19rev c3f5f9950 (clean tree)
Driver oracle & capability record
Part of the 27-part, 44-case twin-factory oracle suite (44/44 passed, generator 0.1.0+policy.12).
| Driver reference | Twin-factory vendor-driver oracle (0.1.0+policy.12) |
|---|---|
| Evidence standing | provisional (register and bus behavior derived from vendor datasheet or driver oracle; not yet hardware-unit verified on two physical samples). |
| Published record | accuracy/twin-factory-oracles-2026-11-19b.json (SHA-256 caa6e32e53c5) |
Key registers & reset values
| Address / Field | Register | Reset / Expected | Purpose |
|---|---|---|---|
0xFE / 0xFF | MANUF / DIE_ID | 0x5449 / 0x2270 | TI manufacturer and INA260 die ID |
0x01 / 0x02 | CURRENT / BUS_V | 1.25 mA / 1.25 mV | Factory-calibrated current and bus voltage |
0x03 | POWER | 10 mW/LSB | Direct power readout with internal 2 mOhm shunt |
Attach with ct CLI
Shell - run firmware with INA260
# Run compiled firmware with INA260 attached on nucleo-l552ze
ct run --json --board nucleo-l552ze --device ina260 build/app.elf
# Run fault-injection suite and emit JUnit XML
ct test run --json --junit results/ina260.xml tests/ina260-fault.suite.yamlFault-injection test snippet (suite.yaml)
tests/ina260-fault.suite.yaml
version: 1
board: nucleo-l552ze
firmware: build/app.elf
tests:
- name: ina260-i2c-nack-and-bad-id
faults:
- at_ms: 30
bus: I2C1
kind: nack
address: 0x40
count: 2
- at_ms: 150
part: ina260
kind: register_override
register: 0xFF
value: 0xFF
expect:
console_contains: "DRIVER_FAULT_DETECTED"
exit_code: 0