Current, Power & ADC

Texas Instruments INA260 digital twin

36 V, 15 A integrated-shunt I2C current and power monitor.

standing: provisionalI2C0x40–0x4F (default 0x40)
VendorTexas InstrumentsCurrent, Power & ADC
InterfaceI2C0x40–0x4F (default 0x40)
Record Status2026-11-19rev c3f5f9950 (clean tree)

Driver oracle & capability record

Part of the 27-part, 44-case twin-factory oracle suite (44/44 passed, generator 0.1.0+policy.12).

Driver referenceTwin-factory vendor-driver oracle (0.1.0+policy.12)
Evidence standingprovisional (register and bus behavior derived from vendor datasheet or driver oracle; not yet hardware-unit verified on two physical samples).
Published recordaccuracy/twin-factory-oracles-2026-11-19b.json (SHA-256 caa6e32e53c5)

Key registers & reset values

Address / FieldRegisterReset / ExpectedPurpose
0xFE / 0xFFMANUF / DIE_ID0x5449 / 0x2270TI manufacturer and INA260 die ID
0x01 / 0x02CURRENT / BUS_V1.25 mA / 1.25 mVFactory-calibrated current and bus voltage
0x03POWER10 mW/LSBDirect power readout with internal 2 mOhm shunt

Attach with ct CLI

Shell - run firmware with INA260
# Run compiled firmware with INA260 attached on nucleo-l552ze
ct run --json --board nucleo-l552ze --device ina260 build/app.elf

# Run fault-injection suite and emit JUnit XML
ct test run --json --junit results/ina260.xml tests/ina260-fault.suite.yaml

Fault-injection test snippet (suite.yaml)

tests/ina260-fault.suite.yaml
version: 1
board: nucleo-l552ze
firmware: build/app.elf
tests:
  - name: ina260-i2c-nack-and-bad-id
    faults:
      - at_ms: 30
        bus: I2C1
        kind: nack
        address: 0x40
        count: 2
      - at_ms: 150
        part: ina260
        kind: register_override
        register: 0xFF
        value: 0xFF
    expect:
      console_contains: "DRIVER_FAULT_DETECTED"
      exit_code: 0

Compatible board twins

More in Current, Power & ADC