Current, Power & ADC

Texas Instruments INA3221 in the datasheet corpus

Triple-channel 26 V high-side shunt and bus voltage monitor with critical/warning alert pins.

standing: provisionalI2C / SMBus0x40-0x43 (A0 pin strap)
VendorTexas InstrumentsCurrent, Power & ADC
InterfaceI2C / SMBus0x40-0x43 (A0 pin strap)
Record StatusCatalog profileDatasheet / behavioral twin

Driver oracle & capability record

Indexed in the CircuitTwin datasheet corpus for multi-rail power telemetry and overcurrent alert testing.

Driver referenceLinux hwmon ina3221 / Zephyr ti,ina3221
Evidence standingprovisional (register and bus behavior derived from vendor datasheet or driver oracle; not yet hardware-unit verified on two physical samples).
Published recordGenerate or inspect locally via ct twin generate (see /docs/twin-generation).

Key registers & reset values

Address / FieldRegisterReset / ExpectedPurpose
0xFE / 0xFFMANUF / DIE_ID0x5449 / 0x3220TI vendor ID and INA3221 die identifier
0x00CONFIG0x7127Channel 1-3 enable, averaging and conversion mode
0x01-0x06CH1..CH3 SHUNT/BUS13-bit signedPer-channel shunt (40 uV/LSB) and bus (8 mV/LSB)

Attach with ct CLI

Shell - run firmware with INA3221
# Run compiled firmware with INA3221 attached on nucleo-f446re
ct run --json --board nucleo-f446re --device ina3221 build/app.elf

# Run fault-injection suite and emit JUnit XML
ct test run --json --junit results/ina3221.xml tests/ina3221-fault.suite.yaml

Fault-injection test snippet (suite.yaml)

tests/ina3221-fault.suite.yaml
version: 1
board: nucleo-f446re
firmware: build/app.elf
tests:
  - name: ina3221-i2c-nack-recovery
    faults:
      - at_ms: 30
        bus: I2C1
        kind: nack
        address: 0x40
        count: 2
      - at_ms: 140
        part: ina3221
        kind: register_override
        register: 0xFF
        value: 0xFF
    expect:
      console_contains: "DRIVER_FAULT_HANDLED"
      exit_code: 0

Compatible board twins

More in Current, Power & ADC