CAN, Ethernet & Transceivers

Texas Instruments SN65HVD230 in the datasheet corpus

3.3 V CAN bus transceiver with slope-control resistor pin (Rs) and listen-only mode.

standing: provisionalCAN PHY + Rs3.3 V TXD/RXD to differential CANH/CANL (up to 1 Mbps)
VendorTexas InstrumentsCAN, Ethernet & Transceivers
InterfaceCAN PHY + Rs3.3 V TXD/RXD to differential CANH/CANL (up to 1 Mbps)
Record StatusCatalog profileDatasheet / behavioral twin

Driver oracle & capability record

Indexed in the CircuitTwin datasheet corpus (can-lin class); pairs directly with ESP32 TWAI and STM32 bxCAN.

Driver referenceTI SN65HVD230 3.3 V CAN PHY profile
Evidence standingprovisional (register and bus behavior derived from vendor datasheet or driver oracle; not yet hardware-unit verified on two physical samples).
Published recordGenerate or inspect locally via ct twin generate (see /docs/twin-generation).

Key registers & reset values

Address / FieldRegisterReset / ExpectedPurpose
Pin RsMODE_SLOPEGND=High-speedHigh-speed, slope-control or high-impedance listen-only mode
BusCANH / CANL120 Ohm termDifferential dominant/recessive signaling on virtual CAN bus

Attach with ct CLI

Shell - run firmware with SN65HVD230
# Run compiled firmware with SN65HVD230 attached on esp32-devkitc
ct run --json --board esp32-devkitc --device sn65hvd230 build/app.elf

# Run fault-injection suite and emit JUnit XML
ct test run --json --junit results/sn65hvd230.xml tests/sn65hvd230-fault.suite.yaml

Fault-injection test snippet (suite.yaml)

tests/sn65hvd230-fault.suite.yaml
version: 1
board: esp32-devkitc
firmware: build/app.elf
tests:
  - name: sn65hvd230-can-ack-drop-and-bus-off
    faults:
      - at_ms: 60
        bus: CAN1
        kind: drop_ack
        count: 16
    expect:
      console_contains: "CAN_BUSOFF_RECOVERED"
      exit_code: 0

Compatible board twins

More in CAN, Ethernet & Transceivers