CAN, Ethernet & Transceivers
Texas Instruments SN65HVD230 in the datasheet corpus
3.3 V CAN bus transceiver with slope-control resistor pin (Rs) and listen-only mode.
VendorTexas InstrumentsCAN, Ethernet & Transceivers
InterfaceCAN PHY + Rs3.3 V TXD/RXD to differential CANH/CANL (up to 1 Mbps)
Record StatusCatalog profileDatasheet / behavioral twin
Driver oracle & capability record
Indexed in the CircuitTwin datasheet corpus (can-lin class); pairs directly with ESP32 TWAI and STM32 bxCAN.
| Driver reference | TI SN65HVD230 3.3 V CAN PHY profile |
|---|---|
| Evidence standing | provisional (register and bus behavior derived from vendor datasheet or driver oracle; not yet hardware-unit verified on two physical samples). |
| Published record | Generate or inspect locally via ct twin generate (see /docs/twin-generation). |
Key registers & reset values
| Address / Field | Register | Reset / Expected | Purpose |
|---|---|---|---|
Pin Rs | MODE_SLOPE | GND=High-speed | High-speed, slope-control or high-impedance listen-only mode |
Bus | CANH / CANL | 120 Ohm term | Differential dominant/recessive signaling on virtual CAN bus |
Attach with ct CLI
Shell - run firmware with SN65HVD230
# Run compiled firmware with SN65HVD230 attached on esp32-devkitc
ct run --json --board esp32-devkitc --device sn65hvd230 build/app.elf
# Run fault-injection suite and emit JUnit XML
ct test run --json --junit results/sn65hvd230.xml tests/sn65hvd230-fault.suite.yamlFault-injection test snippet (suite.yaml)
tests/sn65hvd230-fault.suite.yaml
version: 1
board: esp32-devkitc
firmware: build/app.elf
tests:
- name: sn65hvd230-can-ack-drop-and-bus-off
faults:
- at_ms: 60
bus: CAN1
kind: drop_ack
count: 16
expect:
console_contains: "CAN_BUSOFF_RECOVERED"
exit_code: 0