IMU & Motion

Bosch Sensortec BMI160 digital twin

Low-power 6-axis inertial measurement unit (16-bit accel + gyro).

standing: provisionalI2C / SPII2C 0x68 / 0x69; SPI Mode 0/3
VendorBosch SensortecIMU & Motion
InterfaceI2C / SPII2C 0x68 / 0x69; SPI Mode 0/3
Record Status2026-11-19rev c3f5f9950 (clean tree)

Driver oracle & capability record

Part of the 27-part, 44-case twin-factory oracle suite (44/44 passed, generator 0.1.0+policy.12).

Driver referenceTwin-factory vendor-driver oracle (0.1.0+policy.12)
Evidence standingprovisional (register and bus behavior derived from vendor datasheet or driver oracle; not yet hardware-unit verified on two physical samples).
Published recordaccuracy/twin-factory-oracles-2026-11-19b.json (SHA-256 caa6e32e53c5)

Key registers & reset values

Address / FieldRegisterReset / ExpectedPurpose
0x00CHIP_ID0xD1Bosch BMI160 chip identifier
0x7ECMDWrite-onlyPower mode transitions and soft reset (0xB6)
0x0C–0x17DATA_8..DATA_1916-bit LEGyroscope and accelerometer sample registers

Attach with ct CLI

Shell - run firmware with BMI160
# Run compiled firmware with BMI160 attached on black-pill-f411ce
ct run --json --board black-pill-f411ce --device bmi160 build/app.elf

# Run fault-injection suite and emit JUnit XML
ct test run --json --junit results/bmi160.xml tests/bmi160-fault.suite.yaml

Fault-injection test snippet (suite.yaml)

tests/bmi160-fault.suite.yaml
version: 1
board: black-pill-f411ce
firmware: build/app.elf
tests:
  - name: bmi160-i2c-nack-and-bad-id
    faults:
      - at_ms: 30
        bus: I2C1
        kind: nack
        address: 0x68
        count: 2
      - at_ms: 150
        part: bmi160
        kind: register_override
        register: 0x00
        value: 0xFF
    expect:
      console_contains: "DRIVER_FAULT_DETECTED"
      exit_code: 0

Compatible board twins