IMU & Motion

Bosch Sensortec BMI270 digital twin

Wearable-grade 6-axis IMU with configuration blob load sequence.

standing: provisionalI2C / SPII2C 0x68 / 0x69; SPI Mode 0/3
VendorBosch SensortecIMU & Motion
InterfaceI2C / SPII2C 0x68 / 0x69; SPI Mode 0/3
Record Status2026-11-19rev c3f5f9950 (clean tree)

Driver oracle & capability record

Part of the 27-part, 44-case twin-factory oracle suite (44/44 passed, generator 0.1.0+policy.12).

Driver referenceTwin-factory vendor-driver oracle (0.1.0+policy.12)
Evidence standingprovisional (register and bus behavior derived from vendor datasheet or driver oracle; not yet hardware-unit verified on two physical samples).
Published recordaccuracy/twin-factory-oracles-2026-11-19b.json (SHA-256 caa6e32e53c5)

Key registers & reset values

Address / FieldRegisterReset / ExpectedPurpose
0x00CHIP_ID0x24BMI270 chip identifier
0x21INTERNAL_STATUS0x01 after initReports config load completion
0x0C–0x17DATA_8..DATA_1916-bit LEAccel and gyro data output

Attach with ct CLI

Shell - run firmware with BMI270
# Run compiled firmware with BMI270 attached on nrf52840-dk
ct run --json --board nrf52840-dk --device bmi270 build/app.elf

# Run fault-injection suite and emit JUnit XML
ct test run --json --junit results/bmi270.xml tests/bmi270-fault.suite.yaml

Fault-injection test snippet (suite.yaml)

tests/bmi270-fault.suite.yaml
version: 1
board: nrf52840-dk
firmware: build/app.elf
tests:
  - name: bmi270-i2c-nack-and-bad-id
    faults:
      - at_ms: 30
        bus: I2C1
        kind: nack
        address: 0x68
        count: 2
      - at_ms: 150
        part: bmi270
        kind: register_override
        register: 0x00
        value: 0xFF
    expect:
      console_contains: "DRIVER_FAULT_DETECTED"
      exit_code: 0

Compatible board twins

More in IMU & Motion