Barometer & Pressure
Bosch Sensortec BMP390 in the datasheet corpus
±3 Pa relative-accuracy drone and wearable barometric pressure sensor with 512-byte FIFO.
VendorBosch SensortecBarometer & Pressure
InterfaceI2C / SPII2C 0x76/0x77; SPI Mode 0/3 (up to 10 MHz)
Record StatusCatalog profileDatasheet / behavioral twin
Driver oracle & capability record
Indexed in the CircuitTwin datasheet corpus; shares the Bosch BMP3 Sensor API family with our verified BMP388 twin.
| Driver reference | Bosch BMP3_SensorAPI |
|---|---|
| Evidence standing | provisional (register and bus behavior derived from vendor datasheet or driver oracle; not yet hardware-unit verified on two physical samples). |
| Published record | Generate or inspect locally via ct twin generate (see /docs/twin-generation). |
Key registers & reset values
| Address / Field | Register | Reset / Expected | Purpose |
|---|---|---|---|
0x00 | CHIP_ID | 0x60 | Bosch BMP390 chip identifier (0x50 on BMP388) |
0x1B | PWR_CTRL | 0x00 | Pressure enable, temp enable and power mode |
0x31-0x45 | NVM_PAR_* | 21-byte trim | Factory compensation coefficients |
0x04-0x09 | DATA_0..DATA_5 | 24-bit LE | Raw pressure and temperature words |
Attach with ct CLI
Shell - run firmware with BMP390
# Run compiled firmware with BMP390 attached on nucleo-h743zi2
ct run --json --board nucleo-h743zi2 --device bmp390 build/app.elf
# Run fault-injection suite and emit JUnit XML
ct test run --json --junit results/bmp390.xml tests/bmp390-fault.suite.yamlFault-injection test snippet (suite.yaml)
tests/bmp390-fault.suite.yaml
version: 1
board: nucleo-h743zi2
firmware: build/app.elf
tests:
- name: bmp390-i2c-nack-recovery
faults:
- at_ms: 30
bus: I2C1
kind: nack
address: 0x77
count: 2
- at_ms: 140
part: bmp390
kind: register_override
register: 0x00
value: 0xFF
expect:
console_contains: "DRIVER_FAULT_HANDLED"
exit_code: 0