Barometer & Pressure

Infineon DPS310 digital twin

24-bit barometric pressure sensor (±0.002 hPa precision mode).

standing: provisionalI2C / SPII2C 0x77 / 0x76; SPI Mode 3
VendorInfineonBarometer & Pressure
InterfaceI2C / SPII2C 0x77 / 0x76; SPI Mode 3
Record Status2026-11-19rev c3f5f9950 (clean tree)

Driver oracle & capability record

Part of the 27-part, 44-case twin-factory oracle suite (44/44 passed, generator 0.1.0+policy.12).

Driver referenceTwin-factory vendor-driver oracle (0.1.0+policy.12)
Evidence standingprovisional (register and bus behavior derived from vendor datasheet or driver oracle; not yet hardware-unit verified on two physical samples).
Published recordaccuracy/twin-factory-oracles-2026-11-19b.json (SHA-256 caa6e32e53c5)

Key registers & reset values

Address / FieldRegisterReset / ExpectedPurpose
0x0DPROD_ID0x10Product and revision identifier
0x00–0x05PSR_B2..TMP_B024-bit 2s compRaw pressure and temperature words
0x10–0x21COEFFactory trimCalibration coefficients c0..c30

Attach with ct CLI

Shell - run firmware with DPS310
# Run compiled firmware with DPS310 attached on nucleo-h743zi2
ct run --json --board nucleo-h743zi2 --device dps310 build/app.elf

# Run fault-injection suite and emit JUnit XML
ct test run --json --junit results/dps310.xml tests/dps310-fault.suite.yaml

Fault-injection test snippet (suite.yaml)

tests/dps310-fault.suite.yaml
version: 1
board: nucleo-h743zi2
firmware: build/app.elf
tests:
  - name: dps310-i2c-nack-and-bad-id
    faults:
      - at_ms: 30
        bus: I2C1
        kind: nack
        address: 0x77
        count: 2
      - at_ms: 150
        part: dps310
        kind: register_override
        register: 0x0D
        value: 0xFF
    expect:
      console_contains: "DRIVER_FAULT_DETECTED"
      exit_code: 0

Compatible board twins

More in Barometer & Pressure