IMU & Motion

STMicroelectronics ISM330DHCX in the datasheet corpus

Industrial 6-axis accelerometer and gyroscope rated -40 to +105 C with SPI/I2C host.

standing: provisionalI2C / SPII2C 0x6A/0x6B; SPI Mode 0/3 (up to 10 MHz)
VendorSTMicroelectronicsIMU & Motion
InterfaceI2C / SPII2C 0x6A/0x6B; SPI Mode 0/3 (up to 10 MHz)
Record StatusCatalog profileDatasheet / behavioral twin

Driver oracle & capability record

Indexed in the CircuitTwin industrial datasheet corpus for vibration monitoring and robotics.

Driver referenceSTMicroelectronics ism330dhcx-pid C driver
Evidence standingprovisional (register and bus behavior derived from vendor datasheet or driver oracle; not yet hardware-unit verified on two physical samples).
Published recordGenerate or inspect locally via ct twin generate (see /docs/twin-generation).

Key registers & reset values

Address / FieldRegisterReset / ExpectedPurpose
0x0FWHO_AM_I0x6BFixed ISM330DHCX identifier
0x12CTRL3_C0x04 (IF_INC)Block data update, auto-increment and SW reset
0x1ESTATUS_REG0x00TDA, GDA and XLDA data-ready flags
0x22-0x2DOUTX_L_G..OUTZ_H_A16-bit LE6-axis sample readout

Attach with ct CLI

Shell - run firmware with ISM330DHCX
# Run compiled firmware with ISM330DHCX attached on nucleo-h743zi2
ct run --json --board nucleo-h743zi2 --device ism330dhcx build/app.elf

# Run fault-injection suite and emit JUnit XML
ct test run --json --junit results/ism330dhcx.xml tests/ism330dhcx-fault.suite.yaml

Fault-injection test snippet (suite.yaml)

tests/ism330dhcx-fault.suite.yaml
version: 1
board: nucleo-h743zi2
firmware: build/app.elf
tests:
  - name: ism330dhcx-spi-disconnect-and-fault
    faults:
      - at_ms: 40
        part: ism330dhcx
        kind: bus_disconnect
        duration_ms: 25
    expect:
      console_contains: "SPI_FAULT_HANDLED"
      exit_code: 0

Compatible board twins

More in IMU & Motion